Product Number | Control Mode | Specs | Working Strain | Characteristic |
A4VSO |
LR Hyperbolic power management CZPTtronic proportional management EO |
40,71,a hundred twenty five,one hundred eighty,250, three hundred,355,370,five hundred |
Frequent strain: 35Mpa, Peak strain: 42Mpa. |
Axial piston variable displacement pump with swashplate construction for hydrostatic transmission in open up circuit – The stream charge is proportional to the input speed and displacement. The stream rate can be steplessly modified by modifying the swashplate. – Style of Slot Control Swashplate – Stepless adjustable displacement – Superb oil absorption functionality – Permissible rated working pressure 350 bar – Low sound amount – Prolonged support lifestyle – Driving shaft absorbs axial and radial loads – Substantial energy/bodyweight ratio – Regular composition – Limited manage time – Axle push and pump can be merged – Swashplate swing angle indicator – Set up area is optional – HF oil can be utilised when the operating parameters are reduced. |
Protection recommendations | ||||
one, A4VSO pump is made to work in open circuit. Program design, set up and commissioning require to be performed by skilled experts and distributors |
||||
2, All hydraulic orifices can only be utilised to tighten hydraulic servicing pipelines | ||||
Tightening Torque | ||||
1,All the tightening torques detailed in this sample are greatest values and need to not exceed these values (optimum of internal threads in castings). You should stick to the info supplied by the producer concerning the highest allowable fastening torque of the fittings utilized. · For DIN thirteen-compliant fastening screws, it is suggested that the allowable tightening torque be checked according to VDI 2230 (promulgated in 2003) in all cases. |
||||
two,The housing, especially the coil, could be notably very hot throughout or shortly soon after the procedure of the pump. Please take acceptable security actions (for instance, wear protective apparel). – All info and information offered with the solution have to be complied with |
||||
three,All data and data offered with the merchandise should be complied with.. | ||||
Installation location | ||||
one,Optional. Throughout debugging, oil need to be injected into the pump housing, and it need to be loaded when it is managing. In get to reduce the functioning noise level, all connecting pipes (oil suction, pressure and tank drain pipes) need to be separated from the tank by employing flexible elements |
||||
two,It is required to avoid the use of a single-way valves in tank discharge pipelines. The tank discharge pipeline must be right linked back again to the tank with out shifting the dimensions of the pipeline. There may be irregular circumstance, remember to check with us in time. It can be put in vertically and horizontally. |
||||