CZPT 1MPa-640MPa Air CZPTn CZPT Drinking water CZPT Pressure Booster Examination Pumps for hose/tube/valve testing
We supply the most comprehensive assortment of Air pushed liquid pump models in the industry measured for:
- Capability of greatest force, flow or output horsepower.
- Compatibility with a broad variety of liquids, this kind of as oil, drinking water and chemical programs.
CZPT pumps are air pushed at a generate air force of 1bar to 8bar (14.5 psi to116 psi) by the normal CZPT. Fundamentally the theory of operation is similar to a reciprocating amplifier in which manage of the piston at the conclude position is regulated by a pilot operated four/2 way valve.
CZPT pumps feature a massive air piston joint to a smaller diameter plunger. The pressure ratio is the big difference of these two locations and is the strategy of identifying maximum outlet force. Higher pressures received by using increased stress ratios.CZPT product quantities mirror the pumps nominal stress ratios, even though the technical data signifies actual ratios. The outlet force is easily to established by means of a straightforward air regulator. By multiplying the pressure ratio by the obtainable store air stress, the nominal liquid force can be calculated.
CZPT pumps are self priming. In common it is not essential to use an air line lubricator.
The liquid to be pumped flows into the suction chamber by the up-stroke of the drive piston. By this suction impact, the inlet check valve is opened and the outlet check out valve is closed. The down-stroke generates the force at the liquid facet. The inlet check valve is shut and the outlet check valve is opened by the created pressure. CZPT liquid pumps cycle immediately, where the force is developed up the numbers of cycles gradual down, the pump stops automatically when the output force forces are equivalent. The pump restarts with a slight fall in the outlet pressure or an boost in the air push pressure. Pump efficiency can be influenced by a number of conditions, this kind of as freezing of muffler or pilot valves (which is brought on by dampness in air strains), insufficient inlet air line sizes and filthy filers. Will not lessen the indicated port dimensions and check with CZPT for precise flow situations not proven in charts.
Applications consist of:
- Pressure screening
- Burst(Hydrostatic) screening
- Work holding/electrical power clamping
- Jacking/lifting
- Valve actuator handle
- CZPT cylinder actuation
- Press protection overload products
- Roller tensioning
- Metering
- CZPT lubrication and spraying
- Liquefied gasoline transfer
Crucial features consist of:
- Compressed Air driven – no electric power needed (hook up to regular CZPT)
- In order to lengthen the lifetime of the pump, the driving air force must
not be larger than 8 bar
- No airline lubricator essential
- Pressures to 640Mpa (6400 bar)
- Vast assortment of types with different ratios
- Developed-in-cooling on most versions
- Simple to put in, run and maintain
- Greatest price / efficiency ratio
- No warmth, flame or spark threat and explosion evidence
- CZPT stress holding, what ever the result in of the pressure drop, the CZPT pump will automatically begin, maintain the loop strain constant
DGG Sequence Liquid Pumps(Single performing, solitary air travel head)
- DGG pumps have aluminum bodies and wetted materials of stainless metal or carbon metal ,which
depends on diverse services liquid. CZPT of stainless steel, make them an superb choice
of drinking water application. Large high quality seals, long support lifestyle available.
CZPT specification
Model | Pressure Enhance Ratio | CZPTn air force PL | System to calculate outlet pressure | MAX Outlet Stress(bar)* |
Liquid inlet Link | Liquid outlet Connection | MAX Stream (L/min) |
DGG6 | six:1 | 2-eight bar | 6XPL | forty eight | NPT1/2 | NPT1/two | 29.ninety one |
DGG10 | ten:one | 2-eight bar | 10XPL | 80 | NPT1/two | NPT1/2 | 18.eighty four |
DGG16 | sixteen:one | two-8 bar | 16XPL | 128 | NPT1/2 | NPT1/2 | 12.forty two |
DGG28 | 28:one | two-8 bar | 28XPL | 224 | NPT1/2 | NPT1/two | seven.eleven |
DGG40 | 40:one | two-eight bar | 40XPL | 320 | NPT1/two | NPT1/two | 4.89 |
DGG64 | 64:1 | two-eight bar | 64XPL | 512 | NPT1/two | NPT3/8 | 3.08 |
DGG80 | 80:one | 2-eight bar | 80XPL | 640 | NPT1/two | NPT3/eight | 2.44 |
DGG100 | a hundred:one | 2-eight bar | 100XPL | 800 | NPT1/two | NPT3/eight | one.ninety two |
DGG130 | a hundred thirty:1 | 2-eight bar | 130XPL | 1040 | NPT1/2 | M14X1.5 | 1.forty seven |
DGG175 | 175:one | 2-8 bar | 175XPL | 1400 | NPT3/eight | M14X1.five | 1.fourteen |
DGG255 | 255:one | 2-8 bar | 255XPL | 2040 | NPT1/four | M14X1.5 | .seventy five |
DGG400 | 400:1 | two-8 bar | 400XPL | 3200 | NPT1/4 | M14X1.5 | .forty eight |
DGG510 | 510:one | two-eight bar | 510XPL | 4080 | NPT1/four | M14X1.five | .65 |
DGG800 | 800:one | two-8 bar | 800XPL | 6400 | NPT1/4 | M14X1.5 | .42 |
The outlet liquid strain=CZPTn air strain*boost ratio
In purchase to increase the life time of the pump, the driving air pressure need to not be greater than 8 bar
DGGD Collection Liquid Pumps(Double acting, solitary air drive head)
They are characterised by the identical attributes as the DGG pumps single performing, solitary air push head kinds,
but they have less pulsations and deliver approx. fifty % far more circulation.
CZPT specification
Design | Pressure Enhance Ratio | CZPTn air strain PL | System to calculate outlet strain | MAX Outlet Strain(bar)* |
Liquid inlet Connection | Liquid outlet Relationship | MAX Movement (L/min)** |
DGGD4 | 4:one | two-8 bar | 4XPL | 32 | NPT1/2 | NPT1/two | 70.00 |
DGGD6 | 6:1 | two-8 bar | 6XPL | 48 | NPT1/2 | NPT1/2 | 48.sixty |
DGGD10 | ten:one | two-eight bar | 10XPL | 80 | NPT1/2 | NPT1/two | 30.sixty one |
DGGD16 | 16:one | two-eight bar | 16XPL | 128 | NPT1/two | NPT1/2 | 19.seventy three |
DGGD28 | 28:1 | 2-eight bar | 28XPL | 224 | NPT1/2 | NPT1/2 | eleven.30 |
DGGD40 | 40:one | two-eight bar | 40XPL | 320 | NPT1/two | NPT3/eight | 7.69 |
DGGD64 | 64:1 | two-8 bar | 64XPL | 512 | NPT1/2 | NPT3/eight | 4.94 |
DGGD80 | 80:one | two-8 bar | 80XPL | 640 | NPT1/two | NPT3/eight | three.96 |
DGGD100 | 100:1 | 2-eight bar | 100XPL | 800 | NPT1/two | NPT3/8 | 3.13 |
DGGD130 | a hundred thirty:one | 2-eight bar | 130XPL | 1040 | NPT1/2 | M14*one.5 | 2.forty |
DGGD175 | 175:1 | 2-8 bar | 175XPL | 1400 | NPT3/eight | M14*1.five | one.81 |
DGGD255 | 255:one | two-8 bar | 255XPL | 2040 | NPT1/4 | M14*one.five | one.23 |
DGGD400 | 400:1 | two-eight bar | 400XPL | 3200 | NPT1/four | M14*one.five | .79 |
The outlet liquid stress=CZPTn air stress*boost ratio
In buy to extend the life span of the pump, the driving air force must not be larger than eight bar
CZPT DLS Series CZPT (Air driven) Liquid Booster Program
CZPT- DLS Collection CZPT(Air driven) CZPT Electrical power Packs
CZPT- CZPT power packs(Liquid pump system) are compact and delicacy remedy tailor-made to client distinct demands with air pushed liquid pumps as well as all accessories to be equipped and set up on the body or in shut cabinet.
To operate this program, the force gauges, valves and strain regulators have to be fitted on panels. The outlet stress is simply to be established by means of a easy air regulator. The pump stops immediately when this conclude pressure is reached and restarts with a slight drop in the outlet pressure or an boost in the air push stress. CZPT CZPT electricity packs are available with extensive selection of pressure ratios make these collection of pumps perfect for powering a selection of oil/hydraulic functions. The optimum working pressure up to 640 MPa.
As the strain will be produced by implies of a pneumatically operated pump,the electric powered relationship will not be needed. To run this system, the air pushed liquid pump have to be equipped with the air management unit combined filter and h2o separator, strain-regulating valve, pressure manage gauge as effectively as manual alleviate valve. In this procedure, the pump will be mounted to the stainless steel tank in the shut cabinet in a compact and place saving method. Stress gauges, valves and strain regulators will be equipped on panel.
The sought after working force can be attained by adjusting the driving air pressure. When the driving air strain and the output strain get to the harmony, the pump stops filling stress and the output force stays at the preset value. This hydraulic device can be employed for all kinds of pressure screening and take a look at equipment for investigation and test institutes or for other capabilities necessitating a identified stress.
DLS-DGG series examination bench CZPT specification
Design | Stress Ratio | CZPTn air strain PL | Formulation to estimate outlet pressure | MAX Outlet Force(bar)* |
CZPTn air inlet port |
Large stress Outlet port | MAX Flow (L/min)** |
DLS-DGGD4 | 4:1 | 3-8 bar | 4XPL | 32 | G 1/two | NPT/ZG | 70. |
DLS-DGG6 | 6:one | three-eight bar | 6XPL | 48 | G one/two | NPT/ZG | 29.ninety one |
DLS-DGG10 | ten:one | 3-eight bar | 10XPL | eighty | G 1/two | NPT/ZG | 18.eighty four |
DLS-DGG16 | 16:1 | three-8 bar | 16XPL | 128 | G 1/two | NPT/ZG | twelve.forty two |
DLS-DGG28 | 28:1 | 3-eight bar | 28XPL | 224 | G one/two | NPT/ZG | seven.eleven |
DLS-DGG40 | forty:one | 3-eight bar | 40XPL | 320 | G 1/2 | NPT/ZG | four.89 |
DLS-DGG64 | 64:1 | 3-8 bar | 64XPL | 512 | G 1/two | NPT/ZG | three.08 |
DLS-DGG80 | eighty:1 | 3-8 bar | 80XPL | 640 | G 1/two | NPT/ZG | 2.forty four |
DLS-DGG100 | one hundred:1 | 3-eight bar | 100XPL | 800 | G one/2 | NPT/ZG | 1.92 |
DLS-DGG130 | 130:1 | 3-eight bar | 130XPL | 1040 | G one/2 | NPT/ZG | one.47 |
DLS-DGG175 | 175:1 | 3-8 bar | 175XPL | 1400 | G one/2 | NPT/ZG | one.fourteen |
DLS-DGG255 | 255:1 | 3-8 bar | 255XPL | 2040 | G one/two | NPT/ZG | .seventy five |
DLS-DGG400 | 400:one | 3-8 bar | 400XPL | 3200 | G 1/two | NPT/ZG | .forty eight |
DLS-DGG510 | 510:one | three-eight bar | 510XPL | 4080 | G one/2 | NPT/ZG | .65 |
DLS-DGG800 | 800:1 | three-eight bar | 800XPL | 6400 | G 1/two | NPT/ZG | .42 |
DLS-M sequence examination bench CZPT specification
Product | Strain Boost Ratio | CZPTn air pressure PL | Method to estimate outlet pressure | MAX Outlet Strain(bar)* |
CZPTn air inlet port |
Large stress outlet port | MaxFlow charge(L/min)** |
DLS-DGM4 | 4:one | three-8 bar | 4XPL | 32 | G 1/two | NPT/ZG | fifteen.36 |
DLS-DGM100 | ten:one | three-eight bar | 10XPL | eighty | G 1/2 | NPT/ZG | 7.fifteen |
DLS-DGM16 | sixteen:1 | 3-8 bar | 16XPL | 128 | G one/two | NPT/ZG | four.59 |
DLS-DGM30 | thirty:one | 3-8 bar | 30XPL | 240 | G 1/2 | NPT/ZG | 2.fifty three |
DLS-DGM44 | forty four:1 | three-8 bar | 44XPL | 352 | G one/two | NPT/ZG | one.41 |
DLS-DGM64 | 64:1 | three-8 bar | 64XPL | 512 | G one/2 | NPT/ZG | .95 |
DLS-DGM100 | a hundred:one | 3-8 bar | 100XPL | 800 | G 1/two | NPT/ZG | .64 |
DLS-DGM170 | one hundred seventy:one | 3-eight bar | 170XPL | 1360 | G 1/2 | NPT/ZG | .37 |
CZPT Co., Ltd is the member firm of CZPT Team, which is located in HangZhou metropolis of ZheJiang province in China. With a lot more than fifteen years ordeals in fluid stress trade and controlling field, we offer different varieties of pneumatic and hydraulic booster pumps, systems and options to the buyers all over the entire world. Owing to our ideal item high quality, competitive value as properly as exceptional after-sales support, we have win a wonderful status in the area.
Our main items which includes:
Substantial Force Booster Pumps (Air CZPTn Gas Booster Pump, Air CZPTn Liquid Pump, Air Amplifiers)
Higher Force Methods (Fuel/Liquid Booster Stations,FM200 filling machine, Tube Increasing CZPT)
Higher Force Examination CZPT(CZPT/Burst/Hydrostatic take a look at device,Cylinder check device,
Valve examination bench,Impulse Tests CZPT, and so forth.)
Item Application
Oil CZPT, Gasoline CZPT, CZPT CZPT, Hearth Fighting, Investigation Institutions and so on.
Our support
13 months’ free warranty because the buying date and totally free specialized assistance throughout life span