Solution Description
It can qualitative and quantitation evaluation amid distinct supplies except aspect C, also, the equipment can efficiency nicely in Mg,Al,Si,S,P, and Mn which other machine can not operate nicely. It primarily used in the adhering to fields, these kinds of as steel, fireproofing, non-ferrous industry, the top quality department, the plating thickness testing, ROSH inductor examination etc.
Major Attributes
(one).Correct: Check final results can be near to check soaked chemical approaches.
(2).Quick velocity: Testing big amounts components in the sample only require handful of minutes.
(three).Non-decline: It are unable to harm the actual physical and chemical houses in sample.
(four).Visually: Examination results are current immediately in graph.
(5).CZPT: It can not pollute the environment.
Principal technical parameter
Evaluation elements | Na-U,Mainly are Al,Si,P,S,K,Ca,Ti,V,Fe,Ni,Mn,Pb,Zn,Cu,Sn,Sb,As and so forth |
investigation range | one ppm-99.99% |
measuring time | All the contents examination only in one-2 minutes |
analysis precision | Normal deviation ≤0.08% |
examination mistake | Up to the typical requirments |
radiation dosage | <25 μ sv/h |
environment temperature | fifteen ºC-35 ºC |
Primary allocation
(1). Detection technique
Detector
Type: electric refrigeration SDD detector
Be window thickness: 50um
The ideal resolution: 130eV
CZPT response range: 1keV-50keV
(2).X light-weight tube (for X ray spectrometer)
Voltage: ~ 50kV
Maximum present: one.0mA
Maximum electrical power: 50W
Filament voltage: two.0V
Filament recent: 1.7A
Ray out angle: twelve °
Target: Mo
Be window thickness: .5mm
(three).High-voltage power source
Input voltage: DC+24V ± ten%
Input recent: 4.0A ( highest )
Output voltage: -5KV & 1mA
Maximum energy: 50W
Voltage regulation price: .01% ( from no load to entire load)
Current adjustment rate: .01% ( from no load to complete load)
Ripple factor: .one% ( P-P benefit)
The balance of eight hrs: .05%
(4). Vacuum pump
Vacuum: vacuum test 20Pa restrict vacuum 2Pa
(5). Optical integration design / system / vacuum cavity radiation safety
X light-weight tube, detector, the composite filtertreatment technique, CCD, positioning method, computerized collimator switching system processor optical route are built-in in a shut structure, make sure the steadiness of optical system with a closed optical path method as a vacuum cavity, by way of the loop and the maze effectively by employing X ray maximum power at the very same time to make sure the ray zero overflow.