Touch Display DG-CODG-3000 CZPT COD On-line Analyzer
Solution description
DG-CODG-3000 kind COD automated industrial online analyzer is produced with entirely unbiased mental residence rights of COD automatic testing instrument, be ready to routinely detect COD of any h2o for a prolonged time that in unattended condition.
CZPT parameters
Solution | DG-CODG-3000 Online COD Analyzer |
Regular |
H2o CZPT- CZPT oxygen demand Measurement- Potassium dichromate |
Measuring assortment |
5-1500 mg/L100~5000mg/L500~15000mg/L COD |
Precision |
≤±10% when ≥100mg/L ≤±8mg/L when <100mg/L |
Repeatability |
≤±10% when ≥100mg/L ≤±6mg/L when <100mg/L |
Worth mistake |
≤±10% when ≥100mg/L ≤±6mg/L when <100mg/L |
Measurement time period |
The least measurement interval is 35 minutes, according to the actual water sample, The digestion time can be modified from ten to one hundred twenty minutes. |
Sampling period |
Time interval(fifty five~9999min adjustable by oneself) and Integral time measurement manner |
Calibration interval |
Adjustable in one~99days |
Servicing period of time |
Generally one particular time per month and 30 minutes every single time |
Output |
4~20mA( 2 techniques) RS232,RS485 |
Ambient necessity |
It ought to be indoor and temperature can be adjustable.The suggest temperature is +five~28ºChumidity≤90%(no dew) |
Energy |
AC220±10% V,50±10% Hz,5 A |
Dimension measurement |
Top 1450×Width510×Length 450 mm |
Data saved |
The data can be saved when abnormal alarms and electricity off. |
Show |
Touch display and Command Enter |
Other |
When Reset soon after abnormal alarm and electricity on right after off, the instrument instantly discharges residual reactants in the instrument and automatically resumes operating status. |
Functions
The distinctive design makes this merchandise in contrast to similar merchandise with decrease failure fee, lower maintenance, decrease reagent use and larger expense.
Injection parts: vacuum suction CZPT, and the pump tube between the reagent there is often an air buffer, to steer clear of corrosion of the tubing, even though generating reagent mixing more concise and adaptable.
Sealed Digestion factors: high -temperature higher-pressure digestion program, accelerating the response procedure, to defeat the risky corrosive fuel exposure program products corrosion.
Reagent tube: imported clear modified PTFE hose, diameter better than 1.5mm, decreasing the chance of water-like particles clogging.
Application
1. CZPTal sampling inspection in big watershed.
2. Used by laboratory researchers.
3. Fishery aquaculture environmental monitoring.
4. Monitoring of sewage shops in sewage plants.
5. Rivers, lakes, creeks, and many others.