Dust Evidence Variety Transformer Substation Utilised Dielectric Oil Processing CZPT 9000LPH
Application:
REXON Dust Proof Kind Transformer Substation Utilized Dielectric Oil Processing CZPT 9000LPH, gas and impurities from insulating oil.
This equipment is mostly used for removing trace water, gas and impurities from insulating oil, strengthening the insulating oil efficiency index. It is primarily used to purification of 110KV,220KV,500KV,750KV,1000KV power transmission equipment insulating oil.
Also it applied to treat lower viscosity oils, like insulating oil, turbine oil, and hydraulic oil in the transmission equipment which is lower than 110KV.
Meanwhile, Collection ZYD oil purifier can be employed as impartial vacuum source with capabilities of vacuum drying and vacuum filling.
Insulating oil performance primarily determined by oil’s water content, If the water is not saturation in the oil, it appears as the molecular states If the h2o is saturation in the oil, it appears as the liquid states and continue to be at the base of container.
Underneath the vacuum states, due to the fact the considerably less gas content, the h2o and gas in the oil will be escaped from the oil and evacuated by the vacuum pump.
The increased vacuum worth(Shut to Pa),the increased speed of h2o molecular volatilization(The newest technological innovation, the vacuum oil purifier can achieve to 1 Pa operating vacuum benefit).
The gas and water which dissolved in the oil will turn out to be degassed and fatigued by vacuum pump.
The oil temperature has an effect on vacuum oil purifier functioning effectiveness, the increased temperature, the drinking water molecular get far more kinetic vitality, so it is greater diffused pace of water molecular.
But, exorbitant temperature will trigger fracture of carbon chain for oil molecular, if that will make oil negative.
So we do not suggest the oil temperature excess 80°C. Also the impurity will impact oil dielectric toughness, so the vacuum oil purifier needs higher filtration precision.
Rewards:
Dust Evidence Variety Transformer Substation Utilized Dielectric Oil Processing CZPT 9000LPH, degas and eliminates the impurities far more rapidly, much more completely, and makes the oils restricting voltage-stand up to value much greater. As the bridge-variety vacuum linking system that can purify and also can be an impartial vacuum energy supply, this machine can handle the electric insulation units.
We provide service for moveable, mobile substantial vacuum transformer oil therapy systems that are utilised for transformer oil dehydration and transformer oil degasification as effectively as for other electrical insulating liquids this kind of as silicone fluids. The process maintains the oil’s dielectric strength, eliminates free of charge, soluble drinking water, air-gases and particulate make a difference. The program is designed for processing oils in workshops, storage tanks or right in transformers, numerous applications exterior of the electrical sector, this sort of as for electronic radar gear, vacuum pump sealing oils, brake fluids and refrigeration oils.
Oil technical knowledge soon after REXON Sequence ZYD oil purifier machine remedy:
A. Fuel articles is much less than .1%
B. Impurity degree is much less than 1μm without having cost-free carbon
C. Oil dielectric toughness (breakdown voltage) is far more than 75KV
D. Drinking water content is significantly less than 3 ppm(element per million)
E. Acidity value is significantly less than .01 mgKOH/g
F. Dielectric reduction elements at 90ºC is less than .001
G. Cleanliness degree is significantly less than NAS 1638 Grade five
CZPT Parameters
Parameters | Unit | ZYD-30 | ZYD-fifty | ZYD-one hundred | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Stream Rate | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Doing work Vacuum | Mpa | -.08 ~-.099 | |||||||
Working Stress | Mpa | ≤ .three | |||||||
Temp Selection | ºC | twenty ~eighty | |||||||
Power CZPT | 380V, 50Hz, 3Phase( As for each required) | ||||||||
Operating Sounds | Db | 60 – eighty (Depended on the configuation) | |||||||
Heating Electrical power | KW | thirty | sixty | ninety | 135 | a hundred and fifty | 165 | a hundred and eighty | |
Whole Power | KW | 35 | sixty seven.five | a hundred and one.five | 149 | 164 | 198 | ||
Inlet/Outlet Diam | MM | 25 | 32 | 42 | fifty | fifty | 60 | sixty | |
Weight | KG | 450 | 550 | 750 | 950 | 1200 | 1850 | 2000 | |
Dimension | Duration | MM | 1450 | 1450 | 1750 | 1850 | 1950 | 2050 | 2150 |
Width | MM | 950 | a thousand | 1250 | 1300 | 1350 | 1400 | 1450 | |
Top | MM | 1700 | 1750 | 1950 | 2000 | 2050 | 2100 | 2150 | |
Soon after Treatment | |||||||||
Dielectric CZPT | KV | ≥ 75-eighty five | |||||||
Drinking water Material | PPM | ≤ three | |||||||
Gas Content | % | ≤ .one | |||||||
Particle Size | μ | ≤ three | |||||||
Cleanliness ≤NAS 1638 Grade 5 |
Spare Components:
Packing & Delivery
We are the top manufacture near 20 a long time experience and supply ideal quality and highest value performance oil purification devices. Our oil purifier tools are built by higher high quality uncooked materials with newest sophisticated engineering by many expert specialists and expert employees. We are honest to every single buyer and liable for each and every machine we bought, we offer you great following sales support, whenever when buyer require us, no subject prior to or following purchase, we are available on-line or contacting, to make a quick and instantaneous response to customer.
Consumer Check out
Onsite Venture
We practiced in this industry during all these many years, and have wealthy on-site activities also. Any on-site cases, you should speak to us for a resolution. For in depth merchandise specs, please go away us your email or mobile no. to ship you the catalogs and all specifics. Sincerely hope to cooperate wtih you shortly!